Maintenance-Object Repair Procedures
Table 8-103. Error Log Encode Field Decoding
Field
Variable Name
c
Alarm Type
x
Fault class; see
description for
contributing MOs
pp
Port-network number
Error Log Entries and Test to Clear Values
Error
Aux
Type
Data
18
None
NOTE:
The list config port-network command gives the cabinet number
associated with an EPN.
8-252
Issue 1 May 2002
Values
Description
0
Alarm retired
1
MAJOR or MINOR alarm on any PNC component
0
EAL (Expansion Archangel Link - EXP-PN) carries
CCMS messages
1
PACL (ATM-EI) carries ATM signaling commands
from Call Processing to the remote ATM-EI circuit
packs
2
PNC hardware (providing connectivity of EPN-to-EPN
or -ATM-EI)
5
BFDL (bearer fault detection link) solely for the
purpose of detecting bearer faults
0–63
0–2 for constraint class (this is an internal number;
add 1 for external port number)
Associated Test
busy PNC-DUP
WARNING
On/Off
Alarm Level
Board
ON
Test to Clear Value
release pnc-dup
555-233-143