Advertisement

ATM-EI (Expansion Interface Circuit Pack)
Table 8-85. Expansion Interface 2-Way Transmission Test (#241) — Continued
Error
Test
Code
Result
Description / Recommendation
1033
ABORT
The test cannot run because either the ATM-EI board is not administered, or
there were no other PNs administered that had its ATM-EI board in-service.
1. Ensure that the board is administered as ATM PNC Expansion Interface
2. If the board is administered as ATM-EI circuit pack, then there has been
3. Using status port x (the port-network number where the board is
4. Check the Error Log for Error Type 1281 with Aux Data 27 (board cannot
5. If present, check both the ATM switch and the MultiVantage translations for
6. Repeat Test #241. If it continues to abort with this abort code, replace the
1394
ABORT
1. See
2. Reset the board and see if the problem resolves.
3. Repeat the test.
1395
ABORT
This test cannot run on an ATM-EI circuit pack if it is part of the B-side PNC and
Duplicated PNC is not enabled.
1. If this test needs to run on this ATM-EI circuit pack, enable PNC with the
2. Prevent the system from doing a PNC interchange by executing the set
3. Repeat this test.
1413
ABORT
This test requires the use of a Tone-Clock circuit in each of the EPNs used in
this test. This abort code indicates that a Tone-Clock circuit is absent from one
of the EPNs.
1. Verify that an IPSI or Tone-Clock circuit pack resides in the same EPN as
2. In ATM PNC configurations, make sure that there is at least one other EPN
555-233-143
circuit pack.
some change in the ability of the ATM-EI circuit pack in the other PNs to
communicate with the ATM-EI on the other end of its connection.
administered), see if both ACL and EAL are up to this board. If not, see the
service procedure for SYS-LINK.
talk to the ATM switch). See
procedures.
consistent ATM addresses. Reset the board, and see if the problem
resolves.
board.
Table 8-83 on page 8-197
cannot talk to the ATM switch), and if present, check both the ATM switch
and the MultiVantage translations for consistent ATM addresses.
change system-parameters duplication command.
PNC lock command.
the ATM PNC Expansion Interface circuit pack under test.
besides the EPN where the ATM-EI circuit pack under test resides that
contains a Tone-Clock circuit.
Table 8-83 on page 8-197
(Error Type 1281) with Aux Data 27 (board
Continued on next page
Issue 1 May 2002
for repair
8-207