Avaya S8700 Maintenance Manual page 869

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

ASAI-EPT
Error Log Entries and Test to Clear Values
Table 8-56. ASAI-EPT Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
2 (a)
2-102
None
257 (b)
Any
BRI Layer 3
query
351 (c)
0
none
513 (d)
0
None
769 (e)
0
None
2561 (f)
0
None
2562-
0
None
2566 (g)
2567 (h)
0
None
2568 (i)
0
None
3329 (j)
Any
Signaling Link
status (#626)
3584-
Any
None
3839 (k)
3841 (l)
Any
None
4095
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
2.
Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set options
command.
Notes:
a. Errors of this type indicate violations of the ISDN-BRI signaling protocol.
Timers associated with certain layer-3 messages have expired before a
required response was received. In the following table, the aux data
column indicates which timer has just expired. For more information, refer
to the Avaya ISDN-BRI Specification.
555-233-143
Alarm Level
On/ Off
ASAI-EPT
Board
Any
Any
MAJOR
OFF
2
WARNING
WARNING
OFF
MAJOR
OFF
MAJOR
OFF
WARNING
Test to Clear Value
test ASAI-ADJ
test station ext r 2
test data-module ext r 2
busyout and release
station