Maintenance-Object Repair Procedures
Error Log Entry Notes:
a. Error Type 23: The ATM expansion interface circuit pack is administered
through a change circuit-pack command, but has not been inserted into
the system. Insert the circuit pack.
b. Error Type 125: A wrong circuit pack is located in the slot where this circuit
pack is logically administered. To resolve this problem either remove the
wrong circuit pack or insert the logically-administered circuit pack.
c. Error Type 217: The ATM circuit pack is physically present but has not
been given a personality. Remove the circuit pack or administer it using
the add atm pnc command or the add atm trunk command.
System Technical Demanded Tests: Descriptions
and Error Codes
Test failure is not logged in the error log.
Order of Investigation
Control Channel Loop Around test (#52)
1.
D = Destructive, ND = Nondestructive
8-230
Issue 1 May 2002
Short Test
Long Test
Sequence
Sequence
X
X
1
D/ND
ND