Terminating Trunk Transmission Testing - Avaya S8700 Maintenance Manual

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Terminating Trunk Transmission Testing

Terminating Trunk Transmission
Testing
The Terminating Trunk Transmission (TTT) (non-interactive) feature provides for
extension number access to three tone sequences that can be used for trunk
transmission testing from the far end of the trunks.
The three test types should have extension numbers assigned on the
Maintenance-Related System Parameters form.
Test Type 100:___
Test Type 100 provides:
5.5 seconds of 1004-Hz tone at 0dB
Quiet until disconnect; disconnect is forced after 1 minute.
Test Type 102 provides:
9 seconds of 1004-Hz tone at 0dB
1 second of quiet
This cycle is repeated until disconnect; disconnect is forced after 24 hours.
Test Type 105 provides:
9 seconds of 1004-Hz tone at -16dB
1 second of quiet
9 seconds of 404-Hz tone at -16dB
1 second of quiet
9 seconds of 2804-Hz tone at -16dB
30 seconds of quiet
½ second of 2225-Hz test progress tone
Approximately 5 seconds of quiet
Forced disconnect
555-233-143
Test Type 102:___
Test Type 105:___
Issue 1 May 2002
5-31

Advertisement

Table of Contents
loading

Table of Contents