Maintenance-Object Repair Procedures
Error Log Entries and Test to Clear Values
Table 8-59. ASAI-PT Port Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
1 (a)
(a)
Level 1 Status
inquiry (#621)
513 (b)
0
none
1537 (c)
46210
CRC Error
counter (#623)
3841 (d)
46208
None
3844 (e)
46223
None
3845 (f)
46211
None
3846 (g)
TEI
None
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
2.
Major and Minor alarms may be downgraded to warning alarms based on the value used in the set options
command.
Notes:
a. This error occurs when the Level 1 Status inquiry fails or when the BRI
circuit pack detects that Level 1 has been deactivated on the port. The
Aux Data field contains one of the following values:
Blank
32773
Refer to the repair procedures for Test #621.
b. The circuit pack is having problems transmitting data to the packet bus,
thus affecting the conveyance of signaling information over the D channel.
This error occurs when the packet bus transmit FIFO buffer overflows.
This condition probably indicates a hardware problem as well. The
ASAI-PORT alarm level is MAJOR with aux data 0. Use troubleshooting
procedures for both on-board hardware problems and potential off-board
packet-bus problems.
8-156
Issue 1 May 2002
Alarm Level
ASAI-PORT
Any
2
MAJOR
(b)
2
MAJOR
This indicates that the Level 1 Status inquiry failed.
This is a message from the ASAI-Line circuit pack indicating Level 1
has been deactivated.
On/Off
Board
Test to Clear Value
Any
test port UUCSSpp sh r 1
OFF
test port UUCSSpp sh r 2
ON
OFF
Continued on next page
555-233-143

Advertisement

Table of Contents
loading