13 Axis and Spindle Test Run
13.1 Prerequisites
References
13.1.3

NCK/PLC interface signals

References
13-422
The following terminals must be connected:
I/RF module
Terminal
Significance
63
Impulsfreigabe
64
Drive enable
48
DC–link start
Drive Module
Terminal
Significance
663
Impulsfreigabe
Signal TRUE: +24 V (e.g. from terminal 9)
/FBU/
SIMODRIVE 611 universal Description of Functions
/POS3/ SIMODRIVE SI/CD/CA User Manual
The following NCK/PLC interface signals must be set:
DB number
Byte.Bit
31, ...
0
31, ...
1.3
31, ...
1.4
31, ...
1.5
31, ...
1.6
31, ...
1.7
31, ...
2.1
31, ...
2.2
31, ...
4.3
31, ...
4.4
31, ...
4.6
31, ...
4.7
31, ...
5.0 – 5.5
31, ...
12.0
31, ...
12.1
31, ...
20.1
31, ...
21.7
1) Alternative
2) Checking the function of the hardware limit switch and the relevant interface signals
3) Function–dependent
/FB1/
Description of Functions Basic Functions
A2 Various Interface Signals and Functions
Value
<> 0%
Feedrate/spindle override
FALSE
Axis/spindle disable
FALSE
Followup mode
TRUE
Position measuring system 1
TRUE
Position measuring system 2
TRUE
Override active
TRUE
Controller enable
FALSE
Distance–to–go/Spindle reset
FALSE
Feed stop/spindle stop
FALSE
Traversing–key lock
3)
Traversing key –
3)
Traversing key +
3)
JOG/INC
2)
Hardware limit switch PLUS
2)
Hardware limit switch MINUS
FALSE
Rampfunction generator rapid stop
TRUE
Impulsfreigabe
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
01/2007
Significance
1)
1)