Drive: Configuring The Motors And Encoders - Siemens SINUMERIK 840DiE sl Manual

Hide thumbs Also See for SINUMERIK 840DiE sl:
Table of Contents

Advertisement

9 Drive Commissioning (SINAMICS)
9.2 ONLINE commissioning
9.2.3

Drive: Configuring the motors and encoders

Execution
9-250
Since no motors/encoders are used in the project with DRIVE CliQ interface,
they must be configured manually because the data cannot be determined au-
tomatically without DRIVE CliQ.
Perform the following actions for all drives of the drive units (Drive_1..._3):
1. In the project navigator select Project > <Drive_Unit_Addr10> >Drives >
<Drive> and double–click Drive Navigator.
STARTER – Project
Project Edit Target System View Tools Window Help
Infeed
Input/Output components
Drives
Inserting drives
Drive_1
Drive Navigator
Configuration
Control Logic
Then in the Drive Navigator dialog box, click the "Device configuration" but-
ton and in the Device Configuration dialog box the "Configure the drive" but-
ton.
Run through the following dialogs for configuring the drive unit using the
"Next >" button without making any changes until you reach the motor dia-
log.
2. Enter a unique name for the motor in the "Motor name" field in the motor
configuration dialog box (1).
Select the configuration type:
– Select standard motor from list (2)
– Direct entry of motor data
Configuration – Drive_Unit_Addr10 – Motor
Cl.–loop cntr structure
Power section
Power Unit Connection
Motor
Motor Holding Brake
Encoders
Process data exchange
Summary
4
Drive: Drive_1, DDS 0, MDS 0
Configure the motor:
1
Motor Name:
Motor_01
Motor with DRIVE–CLiQ interface
Read out motor again
2
Select standard motor from list
Enter motor data
3
1FK7 synchronous motor
Motor type:
Motor selection list:
Order no.
Rated...
© Siemens AG 2007 All Rights Reserved