11.3 System data
References
Machine data
Table 11-12
Cycle times: Machine data
Number
General ($MN_ ... )
10050
SYSCLOCK_CYCLE_TIME
10060
POSCTRL_SYSCLOCK_TIME_RA TIO
10062
POSCTRL_CYCLE_DELA Y
10070
IPO_SYSCLOCK_TIME_RA TIO
!
11-304
The maximum value for the NCK CPU time share of 75 % must not be ex-
ceeded. A value greater than 75 % can lead to significant impairment (slowing
down) of Windows XP applications. If necessary, the values must be adapted to
the system clock cycle/position controller cycle (DP cycle time) and/or interpola-
tion cycle.
/FB/
Description of Functions, Special Functions
G3 Cycle Times
Identifier
System clock cycle/only display data; is always
equal to the equidistant PROFIBUS DP cycle.
Note: With 840Di sl, only for display!
Factor for the position control cycle/is set fixed to
the factor 1.
Note: Is not displayed with the 840Di sl!
Position control cycle offset
Factor for the interpolator cycle/can be freely se-
lected in integer multiples.
Caution
If you change the cycle times, check the behavior of the drive in all operating
modes before you finish commissioning.
Note
The smaller the cycle times (PROFIBUS DP cycle) chosen, the greater the
control quality for the drive and the better the surface quality on the workpiece.