Data Description (Md) - Siemens SINUMERIK 840DiE sl Manual

Hide thumbs Also See for SINUMERIK 840DiE sl:
Table of Contents

Advertisement

01/2007
18.3.8

Data description (MD)

General
machine data
13070
MD number
Default setting: 0
Changes effective after POWER ON
Data type: DWORD
Significance:
Axis–specific
machine data
37620
MD number
Default setting: 1
Change valid after NEWCONF
Data type: DOUBLE
Significance:
18.3.9
Alarms
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
18.3 Travel to fixed stop with high–resolution torque reduction
DRIVE_FUNCTION_MASK
Bit–coded screen for selecting the functional scope expected by the NCK with PROFIBUS
drives
Min. input limit: 0
Protection level: 2/7
Meaning of set bits:
Bit 0: Deactivation of the 611U–specific drive alarm mapping
Bit 1: Deactivation of the 611U–specific drive type detection
Bit 2: Deactivation of the 611U–specific parameter accesses encoder drivers
Bit 3: Deactivation of the 611U–specific parameter accesses output drivers
Bit 4: Activation third–party drive: DSC bits (STW1.12/STA1.12)
Bit 5: Deactivation of the 611U–specific drive parking (STW2.7/STA2.7)
Bit 6: Deactivation of the 611U–specific travel to fixed stop (STW2.8/STA2.8)
Bit 7: Deactivation of the 611U–specific internal motor switchover (STA2.9–11)
Bit 8: Deactivation of the 611U–specific ramp block (STW1.13)
Bit 9: Deactivation of the 611U–specific function generator functions (STW1.8/STA1.13)
Bit 14: Selection of non–cyclic DP communication: 0=DPT; 1=DPV1
Bit 15: Deactivation of consistency check for PROFIBUS message frame configuration
CTW: Control word (PDA word in the PROFIDrive message frame to DP slave)
STW:
Status word (PDA word in the PROFIDrive message frame from DP slave)
PDA:
Process data
PROFIBUS_TORQUE_RED_RESOL
Torque reduction resolution on PROFIBUS (LSB weighting)
Min. input limit: 0.005
Protection level: 2/7
The default value 1% refers to the original weighting: The torque limit value is transferred to
the PROFIBUS in increments of 1%; the value 100 in the corresponding PROFIBUS data
cell signifies full torque reduction (i.e. without power).
Bu changing the torque to 0.005%, for example, you can specify value increments of
0.005%, i.e., the torque limit value is incremented more precisely by a factor of 200.
In this case the value 0 is transferred to limit the value to the rated torque. A full torque
reduction (i.e. without power) is given by the value 10000.
To prevent an incorrect adaptation, the set value of the torque must be selected to match
the interpretation of the torque reduction value configured and defined for the drive.
Detailed information on the individual alarms can be found in:
References:
/DA/
For systems with HMI Advanced you can refer to the online help.
18 840Di–specific Data and Functions
Maximum input limit: FFFF FFFF
Applies from SW version: 2.1
Maximum input limit: 10
Applies from SW version: 2.2
Diagnostics Guide
Units: –
Units: %
J
18-519