9 Drive Commissioning (SINAMICS)
9.2 ONLINE commissioning
9.2.8

Control Unit: Error acknowledgement (BICO interconnection)

Execution
Control Logic
Optimize view
Control word, faults/alarms
p2103 BI: 1. Acknowledge faults
Drive_01, r2090: Bit7, BO: PROFIB
p2104 BI: 2. Acknowledge faults
0
7
p2105 BI: 3. Acknowledge faults
0
p2112 BI: External alarm 1
10
1
Control_Unit
9-256
To acknowledge an error for the Control Unit, use the "PROFIBUS PDA1
received" signal from the first drive.
S
Control Unit: p2103 BI: 1. Acknowledge faults
Drive: Drive_1, r2090: Bit7, BO: PROFIBUS PZD1 receive bit--serial
S
Perform the following actions:
1. Double--click Project > Drive_Unit_Addr10 > Control Unit > Control Logic to
open control logic configuration in the project navigator..
2. Click the binector input symbol of signal "p2103 BI: 1. Acknowledge faults"
and from the list select Drive_1 > Further interconnections > r2090: Bit7, BO:
PROFIBUS PZD1 receive bit--serial
p2103 BI: 1. Acknowledge faults
is interconnected with...
Drive_1, r2090: Bit7, BO: PROFIBUS PDA1 receive bit- -serial: : Bit 7 (0=Out/1=In)
Status word, faults/alarms 1
r2139 Bit 0 Acknowledgement running
- - - -
0
r2139 Bit 6 Internal Message 1 active
- - - -
6
r2139 Bit 7 Alarm active
© Siemens AG 2007 All Rights Reserved