Interface Signals - Siemens SINUMERIK 808D ADVANCED Operating Instructions Manual

Parameter manual
Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

32084
HANDWH_STOP_COND
-
Handwheel travel behavior
CTEQ
-
-
Definition of the response of the handwheel travel to axis-specific VDI
Description:
interface signals or the CP-SW limit stop or a stop from an OEM application:
Bit = 0:
Interruption or collection of the distances preset via the handwheel.
Bit = 1:
Cancelation of the traversing motion or no collection.
Bit assignment:
Bit 0: feedrate override
Bit 1: spindle speed override
Bit 2: feedrate stop/spindle stop or CP-SW limit stop or stop from an OEM
application
Bit 3: clamping procedure running (= 0 no effect)
Bit 4: servo enable
Bit 5: pulse enable
For machine axis:
Bit 6 = 0
For handwheel travel, the maximum velocity at which the relevant machine axis
can be traversed is the feedrate set in MD32020 $MA_JOG_VELO.
Bit 6 = 1
For handwheel travel, the maximum velocity at which the relevant machine axis
can be traversed is the feedrate set in MD32000 $MA_MAX_AX_VELO.
Bit 7 = 0
The override is active in handwheel travel.
Bit 7 = 1
The override is always assumed to be 100% for handwheel travel, regardless of
how the override switch is set.
Exception: override 0% is always active.
Bit 8 = 0
The override is active with DRF
Bit 8 = 1
The override is always assumed to be 100% for DRF, regardless of how the
override switch is set.
Exception: override 0% is always active.
Bit 9 = 0
For handwheel travel, the maximum possible velocity with revolutional fee-
drate is
- with the feedrate in SD41120 $SN_JOG_REV_SET_VELO or
- the feedrate in MD32050 $MA_JOG_REV_VELO or
- in the case of rapid traverse with MD32040 $MA_JOG_REV_VELO_RAPID
of the relevant machine axis calculated with the spindle or rotary axis fee-
drate.
Bit 9 = 1
For handwheel travel, the maximum possible velocity is with the revolutional
feedrate in MD32000 $MA_MAX_AX_VELO of the relevant machine axis. (see also
bit 6)