11 NCK Commissioning with HMI Advanced
11.11NCK/PLC diagnostics

11.11.2 Menu: Settings

Operating path
Commiss- -
CHAN1
ioning
Channel RESET
Settings
Signal input for shutdown behavior
Diagnostics
Settings
Fig. 11-35 Menu: Settings
Modifying data
Group box:
Settings
11-410
The menu for the SINUMERIK 840Di sl specific settings is in the following oper-
ating path:
S
Operating area switchover > Commissioning > NC/PLC Diagnosis > Set-
tings
JOG Ref
MPF0
Program aborted
Signal source
deactivated
Signal level
- -
When switching to the menu the data displayed become read--only. To change
the data, press the "Change" softkey first.
The following functions are grouped together via the "Settings" group box:
Signal input for shutdown behavior: Signal source
S
This selection field is for configuring the digital input used for the shutdown
signal of the UPS:
S
deactivated
No input signal is present.
NCK input 0...3
S
The shutdown signal of the UPS is connected to the configured digital
input of the MCI board extension module (See Section 2.3.3, Page 2-57).
ROV