Siemens SINUMERIK 840DiE sl Manual page 396

Hide thumbs Also See for SINUMERIK 840DiE sl:
Table of Contents

Advertisement

11 NCK Commissioning with HMI Advanced
11.7 Digital and analog I/O devices
Number of outputs
bytes
Hardware
assignment:
input bytes
Hardware
assignment:
output bytes
11-396
ET200
2 output bytes
ADI4
2 output bytes
Note
Although only 4 output bytes are used, 5 must be declared. The 1st output byte
is always assigned to the MCI board extension module even if it is not
installed:
– MD10360: FASTIO_DIG_NUM_OUTPUTS = 5
The following input bytes are used by the NCK:
ET200
Both input bytes of the input module (slot 6)
– MD10366: HW_ASSIGN_DIG_FASTIN[0] = H05000080 (128
– MD10366: HW_ASSIGN_DIG_FASTIN[1] = H05000081 (129
The 4th of the 4 input bytes of the signal module (slot 7)
– MD10366: HW_ASSIGN_DIG_FASTIN[2] = H05000085 (133
ADI4
The high byte of the input word (slot 21)
– MD10366: HW_ASSIGN_DIG_FASTIN[3] = H050010E7 (4327
The following output bytes are used by the NCK:
ET200
The 1st output byte of the output modules (slots 4 and 5)
– MD10368: HW_ASSIGN_DIG_FASTOUT[0] = H05000080 (128
– MD10368: HW_ASSIGN_DIG_FASTOUT[1] = H05000082 (130
ADI4
Both output bytes of the output word (slot 22)
– MD10366: HW_ASSIGN_DIG_FASTOUT[2] = H050010E6 (4326
– MD10366: HW_ASSIGN_DIG_FASTOUT[3] = H050010E7 (4327
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
01/2007
)
D
)
D
)
D
)
D
)
D
)
D
)
D
)
D