6 PLC Commissioning
6.3 Creating a SIMATIC S7 project
6-148
Properties – PG/PC
General
Interface
1
Name
New interface – Type selection
Type:
2
New...
4. After confirming with OK, the properties dialog box of the Ethernet interface
is displayed. Select the tab: Parameter (1) tab and enter the IP address and
subnet mask of the PG/PC (2).
Note
Determining the IP address and subnet mask of the PG/PC:
On the PG/PC: Windows XP taskbar: Start > Run, Command: ipconfig
Select the Ethernet connection already parameterized in the previous Sec-
tion 6.3.8, Page 6-145 as the subnet: "Ethernet (1)" (3)
Click OK to confirm the dialog.
Properties – Ethernet interface
General
Parameter
Set the MAC address/use ISO protocol
MAC address:
09–00–07–01–00–02
IP protocol is used
IP address:
157.174.219.45
255.255.248.0
Subnet mask:
Subnet:
––– not networked
–––
Ethernet (1)
3
OK
Notice
The MAC address, IP address and subnet mask in the figure above are only
sample values!
Assignment
Industrial Ethernet
MPI
3
PROFIBUS
OK
Cancel
1
When selecting a subnet,
the next available addresses are suggested.
2
Gateway
No router
Use router
Address:
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
01/2007
Subnet
Delete
Help
157.174.219.45
New...
Properties...
Delete
Cancel
Help