Siemens SINUMERIK 840DiE sl Manual page 67

Hide thumbs Also See for SINUMERIK 840DiE sl:
Table of Contents

Advertisement

01/2007
Options
Mounting bracket
Spare part
installation
References
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
S
Mounting position and location to a large degree variable
S
Screen resolution
S
Power Supply:
S
Interfaces to peripheral devices:
– 1 x PROFIBUS DP (max. 12 Mbaud)
– 1 x DVI–I interface for external monitor
– 2 x Ethernet connections 10/100 Mbaud
– 1 x CF card shaft (covered)
– 4 x high–speed USB ports (USB 2.0)
S
Interfaces to operator panel front:
– LVDS panel interface (channel 1 and optional channel 2)
– I/O USB panel interface
– Additional high–speed USB port (USB 2.0)
S
No. of slots
– 1 x PCI (length: max. 265 mm, occupied by the MCI board)
– 1 x PCI (length: max. 175 mm, occupied with option MCI board exten-
sion slot variant)
The following options are offered:
S
Memory expansion up to max. 2048 MB
S
External floppy disk drive
Mounting brackets are required to mount the PCU directly behind the operator
panel front:
– Mounting bracket MLFB: 6FC5 248–0AF20–2AA0
When installing spare parts please note the following:
S
When replacing the PCU, remove the mounting brackets (MLFB 6FC5
248–0AF20–2AA0) from the defective PCU and attach to the replacement
part.
For the complete documentation on the PCU 50.3, please refer to:
References:
/BH/ Operator Components Manual
Component PCU 50.3
2 Hardware Descriptions
2.5 SINUMERIK Industrial PC
640 x 480, up to max. 1600 x 1200
24 V DC
2-67

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di sl

Table of Contents