Axis and Spindle Test Run
13.1 Requirements
13.1.2
Drives: SIMODRIVE
Relevant terminals
Applies to the following SIMODRIVE drives:
● SIMODRIVE 611 universal/universal E
● SIMODRIVE POSMO SI, CD/CA
The following terminals must be connected:
I/RF module
Drive Module
Signal TRUE: +24 V (e.g. from terminal 9)
References:
/FBU/ Function Manual SIMODRIVE 611 universal
/POS3/ User Manual - SIMODRIVE SI/CD/CA
13.1.3
NC/PLC interface signals
Relevant NC/PLC interface signals
The following NC/PLC interface signals must be set:
DB number
31, ...
31, ...
31, ...
31, ...
31, ...
31, ...
31, ...
31, ...
31, ...
31, ...
31, ...
31, ...
502
Terminal
Description
63
Pulse enable
64
Drive enable
48
DC-link start
Terminal
Description
663
Pulse enable
Byte.Bit
0
1.3
1.4
1.5
1.6
1.7
2.1
2.2
4.3
4.4
4.6
4.7
Value
Description
<> 0%
Feedrate/spindle override
FALSE
Axis/spindle disable
FALSE
Follow-up mode
TRUE
Position measuring system 1
TRUE
Position measuring system 2
TRUE
Override active
TRUE
Controller enable
FALSE
Distance-to-go/Spindle reset
FALSE
Feed stop/spindle stop
FALSE
Traversing-key lock
Traversing key -
3)
Traversing key +
3)
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
1)
1)
Manual