Configuration Example - Siemens SINUMERIK 840DiE sl Manual

Hide thumbs Also See for SINUMERIK 840DiE sl:
Table of Contents

Advertisement

11 NCK Commissioning with HMI Advanced
11.7 Digital and analog I/O devices
11.7.6

Configuration example

840Di sl (configuration) –– 840Di sl_ET200_ADI4
(0) UR
PLC317–2DP M/S 2AJ10
2
DP master
X2
4
CP 342–5
Fig. 11-33 Example configuration: SINUMERIK 840Di sl with ET200 and ADI4
11-394
R
Computational time of position controller and/or signal module
Dx
Exchange of user data between DP master and DP slaves
MSG
Acyclic services (e.g. DP/V1, pass token)
RES
Reserve: "active break" until the equidistant cycle has elapsed
Set the system variables, e.g. $A_OUT[8] in the part program or
1
synchronized action
Transmit the output signal to the signal module on
2
PROFIBUS DP
Connect the signal to the output of the module.
3
In the following configuration example, the following digital input/outputs are
available to the NCK:
ET200
– 24 digital inputs
– 16 digital outputs
ADI4
– 8 digital inputs
– 16 digital outputs
Note
S
The I/O addresses of the modules are assigned automatically by "HW
Config" (manual adjustment is possible).
S
Each I/O address refers to an input/output byte.
PROFIBUS(2): DP master system (2)
(5) IM 153
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
01/2007
(6) ADI4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di sl

Table of Contents