8 PROFIBUS DP Communication

8.4 SIMATIC I/O devices (ET200...)

8.4
SIMATIC I/O devices (ET200...)
8.5
DP slave: I/O Module PP72/48
8.5.1
GSD file
8-192
The SIMATIC I/O devices of the series ET200, e.g. ET200M, are integrated into
the S7 project as usual using HW Config and configured.
Note
To simplify parameterization of the isochronous communication on the
PROFIBUS DP, you must first insert all the SIMATIC I/Os you require into the
configuration before parameterization of the DP drives (e.g. DP slave 611U or
ADI4).
Note
To check whether a module selected from the hardware catalog complies with
the module in the automation system, the following procedure is
recommended:
1. Note the MLFB numbers of all modules used in the automation system.
2. Select the appropriate module from the hardware catalog and compare the
order number (MLFB) with the MLFB number of the module displayed in the
hardware catalog. Both MLFB numbers must be the same.
A PP72/48 I/O module is parameterized with a GSD file.
– The GSD file is part of the SINUMERIK 840Di sl software. See Section
1.2, Page 1-34: SIMATIC add–on software: GSD filefor I/O modules
PP72/48
– For installation of a GSD file, see Section 8.1.5, Page 8-182: GSD files.
Note
To make parameterization of isochronous communication with PROFIBUS DP
easier, we recommend inserting all required DP slaves 611U into the
configuration before setting the times for isochronous communication.
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
01/2007