11 NCK Commissioning with HMI Advanced
11.4 Memory configuration
11.4
Memory configuration
Hardware
configuration
User data
Effectivity
11-306
The dynamic (DRAM) or static (SRAM) memory available depends on the hard-
ware configuration of the components used (PCU and MCI board) and the
memory available for SINUMERIK 840Di sl.
PCU 50.3–C/1.5 GHz
PCU 50.3–P/2.0 GHz
MCI board
1) DRAM component (main memory) occupied by SINUMERIK 840Di sl
and thus no longer available for Windows XP.
2) The SRAM memory of the MCI board is divided into:
– Part programs and manufacturer cycles: 3 MB
– User data: 1 MB
– Siemens cycles: 1 MB
The individual memory areas of the user data are set to reasonable default val-
ues during general reset of the NCK. To obtain optimum utilization of the user
memory the size of the individual data areas can be set for, e.g.:
S
Part programs
S
Tool management
S
Tool offsets
S
User data
S
Arithmetic variables
S
Compensations
S
Protection zones
S
Frames
(see Section 11.4.2, Page 11-308):
The memory must be sectionalized before commencement of the actual NCK
commissioning because all user data (e.g. part programs, tool offsets) will be
lost during the changes.
Machine data, setting data, and option data are not lost when the memory is
reorganized.
The machine data of the memory configuration are activated by power ON.
References:
/FB/
Description of Functions
S7 Memory Configuration
SDRAM
DRAM
Maximum
for 840Di sl
512 MB
Approx. 16 MB
1024 MB
Approx. 16 MB
–
–
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
01/2007
SRAM
1)
–
–
2)
5 MB