01/2007
7.2

SINUMERIK 840Di sl commissioning tool: SinuCom NC

7.3
SINAMICS drive commissioning tool: STARTER
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) - - 01/2007 Edition
7.2 SINUMERIK 840Di sl commissioning tool: SinuCom NC
The SINUMERIK 840Di sl commissioning tool "SinuCom NC" communicates
with a SINUMERIK 840Di sl exclusively via an Ethernet connection independent
of the installation location (externally or internally).
Start the SinuCom NC Connect Wizard from the Windows XP Start menu to
parameterize the Ethernet connection: Start > Programs > SinuCom > NC
Connect Wizard
Make the following settings in the NC Connect Wizard:
1. Control Mode: 840Di (any)
2. Port: RJ--45 (solutionline ONLY)
3. IP address:
The IP address by which the SinuCom NC communicates with the
SINUMERIK 840Di sl depends on where SinuCom NC is installed:
--
PG/PC (external connection)
Enter the IP address of the PCU Ethernet interface used (Ethernet 1:
company network or Ethernet 2: system network).
To determine the IP address, see Section 7.1.2, Page 7-161.
--
SINUMERIK 840Di sl PCU (internal connection)
Enter the IP address: 127.0.0.1 (local host).
The SINAMICS STARTER drive commissioning tool communicates with the
SINAMCS S120 drives via PROFIBUS only.
If the STARTER is connected to the SINUMERIK 840Di sl via Ethernet link,
within the framework of the S7 project for configuring the PLC the PG/PC on
which the STARTER runs must be linked by means of SIMATIC STEP 7 "Net-
Pro" with the SINUMERIK 840Di sl. The SINUMERIK 840Di sl PLC then routes
the STARTER on the PROFIBUS to the SINAMICS drives.
The networking is described in: Section 6.3.9, Page 6-147.
Note
The SINAMICS STARTER drive commissioning tool can currently only be
operated on a SINUMERIK 840Di sl PCU if at least one of the two Ethernet
interfaces is active. To do this, at least one component must be connected to
the relevant Ethernet interface, e.g. an "MCP 483C IE" machine control panel to
Ethernet interface 2 (system network), and communicate with the SINUMERIK
840Di sl.
7 Ethernet Communication
7-163