6 PLC Commissioning
6.3 Creating a SIMATIC S7 project
6.3.6
Parameterizing the PROFIBUS interface (X102) (optional)
HW Config – [SINUMERIK (configuration) –– SIN840Di sl]
Station Edit Insert Target System View Tools Window Help
(0) 840Di sl
2
PLC 317–2DP 2AJ10
X1
MPI/DP
X2
DP
4
NCK 840D sl
5
CP 840D sl
(0) 840Di sl
Slot
Module...
2
PLC 317–2DP 2AJ10
X1
MPI/DP
X2
DP
4
NCK 840D sl
5
CP 840D sl
Fig. 6-6
HW Config: SINUMERIK 840Di sl Rack
Dialog box
6-144
When you have completed the "Properties – PROFIBUS DP Interface" dialog
box (see previous Section 6.3.5, Page 6-143) the 840Di sl Rack is displayed in
the Station window.
PROFIBUS(1): DP master system(1)
Order number
6FC5 317–2AJ10–0AB0
To parameterize the PROFIBUS interface (X102) as for slot X1, set the following
parameters:
S
Interface type
S
Transmission rate
Double–click module: MPI/DP, slot X1 in the 840Di sl Rack, to open the MPI/DP
Properties dialog box.
Dialog box: MPI/DP Properties
Tab: General
Name: <Designation of 2nd DP interface>
Group: Interface
Type: PROFIBUS
Button: "Properties..."
Dialog box: Properties – PROFIBUS MPI/DP Interface
Tab: Parameter
Address: <Address>
Button: "New..."
Search:
Profile:
Fi...
M.. E...
A... K...
V2.1
8191
8190
256*
V0.0
272.. 272..
840Disl PLC317–2DP_2AJ10
SINUMERIK 840Di sl
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
01/2007
Default
PROFIBUS DP
PROFIBUS PA
PROFINET IO
SIMATIC 300
C7
CP–300
CPU –300
FM –300
IM –300
M7 EXTENSION
Gateway
PS–300
RACK–300
SM –300
SINUMERIK
840Di sl
840Di sl