Execution
9.2.15
Drive: Running the motor
9-262
After completing the configuration, you must load and save the parameters in
the drive unit.
Perform the following actions for each drive unit:
1. Access the drive unit with the PG/PC online.
2. Now load the project data into the drive unit: Right–click Drive_Unit_Addr10
> Target system > Load to target system... in the project navigator.
3. Save the project data in the drive unit on the CF card: Click
Drive_Unit_Addr10 > Target system > Copy RAM to ROM... in the project
navigator.
You can test the configuration loaded into the drive unit by running the motors of
the drives using the operator control panel in the STARTER.
This can be done once the pulses have been enabled for the infeed and
line/DC link identification has been activated. The infeed then switches to oper-
ational mode.
Note
For more information about the operator control panel: see SINAMICS S120
Getting Started with the STARTER Commissioning Tool.
For more information about line/DC–link identification, see SINAMICS S120
Function Manual.