11 NCK Commissioning with HMI Advanced
11.3 System data
NCK:
Position controller
PROFIBUS DP
Communication
DP slaves:
Drives
Fig. 11-2
Position control cycle offset compared to PROFIBUS DP cycle
Interpolation cycle
NCK CPU time
share
11-302
T
M
R
T
DX
MSG
RES
GC
Dx
Dx
Dx
R R R
R R R
R R R
R R R
R R R
R R R
Key to Fig. 11-2:
T
CPU time required by position controller
Pos
T
DP cycle time: DP cycle time
DP
T
Data exchange time: Sum of transfer times of all
DX
DP slaves
T
Master time: Offset of the start time for NCK
M
position control
GC
Global control: Broadcast message for cyclic
synchronization of the equidistance between DP master
and DP slaves
R
CPU time
Dx
Exchange of user data between DP master and DP slaves
MSG
Acyclic services (e.g. DP/V1, pass token)
RES
Reserve: "active break" until the equidistant cycle has elapsed
The interpolator cycle may be chosen freely as a whole multiple of the position
control cycle.
S
MD10070: $MN_IPO_SYSCLOCK_TIME_RATIO (factor for interpolator
cycle)
The processor power of the PCU must be shared between the NCK and Win-
dows XP. The parameterized CPU time share of the NCK is the maximum value
that the NCK will only use in the worst case. If the NCK requires less CPU time
in cyclical operation, it will cede it dynamically to Windows XP.
T
DP
T
Pos
R
MSG
RES
GC
Dx
Dx
Dx
R R R R R R
R R R
R R R
R R R
R R R
R R R
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
01/2007
R
R R R
R R R

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di sl

Table of Contents