5 Power On and Power- -Up
5.3 Booting
5.3.4

Power up after reinstallation/update of the 840Di sl software

5-114
SINUMERIK 840Di sl NCK/PLC
Alarm: Old backup of user data loaded into MCI card.
The user data were saved on 07.07.2000 10:30
An NC alarm is also generated, which is displayed on the respective
SINUMERIK 840Di sl user interface (840Di start--up, HMI Advanced, etc.):
Alarm: "4065 Battery--backed memory has been restored from the hard
S
disk (possible data loss)"
To acknowledge the alarm you must first acknowledge the alarm itself with a
special operation before executing the required NCK POWER ON Reset. See
Section 11.11.1, Page 11-406et sqq.
If the 840Di sl software is reinstalled on an operational SINUMERIK 840Di sl,
the user data saved in the SRAM of the MCI board is retained.
To achieve this, it is essential that the current NC and PLC software version
complies with the software version with which the battery--backed user data of
the SRAM have been created.
The SINUMERIK 840Di sl is thus ready again immediately.
Responses
A note will appear in a message box, which must be acknowledged with "OK":
SINUMERIK 840Di sl NCK/PLC
Note: User data from MCI card used.
Notice
If the buffered user data is not going to be used again, the SINUMERIK
840Di sl must be recommissioned.
© Siemens AG 2007 All Rights Reserved