Preconditions For An Online Connection - Siemens SINUMERIK 840DiE sl Manual

Hide thumbs Also See for SINUMERIK 840DiE sl:
Table of Contents

Advertisement

01/2007
10.1.2

Preconditions for an online connection

10.1.3
Setting a PROFIBUS address (SIMODRIVE 611 universal/E)
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) - - 01/2007 Edition
10.1 SIMODRIVE 611 universal/E, POSMO CD/CA and SI
To be able to establish an online connection between SimoCom U and the
SIMODRIVE 611 universal drives connected to a SINUMERIK 840Di sl using
PROFIBUS DP, the following preconditions must be fulfilled:
S
SimoCom U must be installed.
--
For installing SimoCom U, see Section 10.2, Page 10-283
S
A PROFIBUS connection must exist from the PROFIBUS interface of the
MCI board to all drives.
--
For network rules, see Section 8.1.5, Page 8-178
With all drives, the PROFIBUS address must be set.
S
--
For SIMODRIVE 611 universal/E see Section 10.1.3, Page 10-277
--
For SIMODRIVE POSMO CD/CA and SI, see Section 10.1.4, Page
10-279
S
The MPI interface of the SINUMERIK 840Di sl PLC must be networked
--
For networking the MPI interface, see Section 6.3.7, Page 6-145
S
The configuration must be loaded into the PLC.
--
For creating an S7 project, see Section 6.3, Page 6-139
--
For loading the PLC, see Section 8.3.3, Page 8-185
The MPI interface must be set on the "SINUMERIK MCI Card (MPI)".
S
--
For setting the MPI interface, see Section 10.1.5 , Page 10-280
S
The routing information must be set.
--
For setting the routing Information, see Section 10.1.6, Page 10-281
For SimoCom U to be able to enter online operation with the SIMODRIVE drives
connected to the PROFIBUS, the PROFIBUS address specified in the S7 proj-
ect (see Section 6.3, Page 6-139f) must be set on DP slave 611U or UE in
question using the display and operator unit.
+
Fig. 10-1
Display and control unit
10 Drive Commissioning (SIMODRIVE)
Display
Control unit
P
- -
10-277