11.7.6
Configuration example
In the following configuration example, the following digital input/outputs are available to the
NC:
ET 200
● 24 digital inputs
● 16 digital outputs
ADI4
● 8 digital inputs
● 16 digital outputs
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
M
Master time: Offset of the start time for NC position control
Global Control: Broadcast message for cyclic convergence of the equidistance between
DP master and DP slaves
Computational time of position controller or signal module
Useful data exchange between the DP master and DP slaves
Acyclic services (e.g. DP/V1, pass token)
Reserve: "Active break" until the equidistant cycle has expired
Set the system variables, e.g. $A_OUT[8] in the part program or synchronized action
Transmit the output signal to the signal module via the PROFIBUS DP
Connect the signal to the output of the module.
Note
The following is to be taken into account:
• The I/O addresses of the modules are assigned automatically by "HW Config" (manual
adjustment is possible).
• Each I/O address is related to an input/output byte.
NC Commissioning with HMI Advanced
11.7 Digital and analog I/O devices
473