Siemens SINUMERIK 840Di sl Commissioning Manual page 368

Hide thumbs Also See for SINUMERIK 840Di sl:
Table of Contents

Advertisement

NC Commissioning with HMI Advanced
11.3 System data
User-defined
The user can define different input/output units for machine and setting data.
For this there must be an adjustment between the newly selected input/output units and the
internal units via the following MD:
● MD10220 $MN_SCALING_USER_DEF_MASK (activation of standardizing factors) and
● MD10230 $MN_SCALING_FACTORS_USER_DEF[n] (standardizing factors of the
The following applies:
Selected I/O unit =
MD10230 $MN_SCALING_FACTORS_USER_DEF[n] * internal unit
The selected I/O unit, expressed in the internal units 1 mm, 1 degree and 1 s must therefore
be entered in MD10230 $MN_SCALING_FACTORS_USER_DEF[n].
Table 11-6
Physical unit
Linear position
Angular position
Linear velocity
Angular velocity
Linear acceleration
Angular acceleration
Linear jerk
Angular jerk
Time
368
physical quantities)
Bit number and index for user definition
MD10220:
Bit number
0
1
2
3
4
5
6
7
8
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
MD10230:
Index n
0
1
2
3
4
5
6
7
8
Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840die sl control

Table of Contents