IP address and subnet mask
After installation of the protocol and to simplify setting up communication with the PCU, it is
necessary to check the IP address and the subnet mask and set them, if necessary:
IP address
We recommend using an IP address from the address range used by Windows XP for
automatic configuration, if no DHCP server is accessible (Automatic Private IP Addressing:
169.254.x.x).
The last two digits must be in the range of 1 to 254.
● 169.254. 10. 1
Subnet mask
The subnet screen must be permanently set to the specified value:
● 255.255. 0. 0
Dialog: Continuation
Dialog: Network
Computer name and workgroup
Because it is a PTP link, any computer name and workgroup may be selected.
Dialog: Continuation
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
Tab: Protocols
Button: "Properties..."
Dialog: Properties of Microsoft TCP/IP
Specify IP address
Specify IP address
IP Address: <169.254. 10. 1>
Subnet mask: <255.255. 0. 0>
OK
Tab: Identification
Button: "Change..."
Dialog: Identification change
Computer name: <COMPUTER NAME>
Workgroup: <WORKGROUP>
OK
Software installation/update and data backup
16.1 PTP network connection
553