Configuring The External Computer (Windows Nt) - Siemens SINUMERIK 840Di sl Commissioning Manual

Hide thumbs Also See for SINUMERIK 840Di sl:
Table of Contents

Advertisement

Software installation/update and data backup
16.1 PTP network connection
TCP/IP network protocol
The network protocol used is: TCP/IP. TCP/IP permits high data transmission rates and it is
simple to configure. TCP/IP is already pre-configured in the basic PCU software.
Requirements on the ext. computer
The following requirements must apply on the external computer:
● A network adapter is installed.
● The TCP/IP network protocol is installed.
● The external computer is connected to the PCU via a crossed Ethernet cable.
● The IP address of the external computer is within the same subnet as the PCU.
● A directory is shared as the network drive.
16.1.2

Configuring the external computer (Windows NT)

This section illustrates how to make and check settings for network configuration on the
external computer:
● TCP/IP protocol
● IP address and subnet mask
● Computer name and workgroup
● Service: "Server service"
● Directory sharing
TCP/IP protocol
The installed network protocols are displayed in the "Protocols" tab via the network dialog of
the system control (Windows taskbar Start > Settings > System Control > Network). If the
TCP/IP protocol is not shown, it can be installed now.
Dialog: Beginning
Dialog: Network
552
Tab: Protocols
Button: "Add..."
Dialog: Network protocol selection
Network protocol: TCP/IP protocol
Note:
The query for DHCP is to answered with "No".
OK
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840die sl control

Table of Contents