Ethernet communication
7.6 HT 8
Figure 7-9
Softkey <TCU Settings>
The dialog for setting the TCU parameters is called via the <TCU Settings > softkey. The
following parameters can be changed:
● Individual Mode: no (recommended setting), yes
● EKS index: <
● Enable direct keys: no, yes
"MCP Address" and "TCU Index" parameters
The identifier of the power supply unit set is taken as MCP address and TCU index via the
rotary coding switches S1 and S2. The values cannot be changed via the TCU firmware.
"TCU Name" parameter
The name of the TCU or HT 8 is generated automatically. The name is formed from "DIP"
followed by the decimal value of the identifier of the power supply unit. The name cannot be
changed via the TCU firmware.
Table 7-4
7.6.4

Parameterization of the HT 8 via the system network center

Change the "Name" parameter
The name was set to "DIP<
the system network center. To do so, proceed as follows:
1. Start the system network center via the corresponding connection on the service desktop.
2. Open the tab: OPs
3. Double-click on the line in the "Available OPs" area in which the HT 8 whose Name
204
<Recall> and <Menu Select> keys
Index
>
Example
Identifier: 27
H
parameter is to be changed is displayed. In the example: "DIP39":
= 39
TCU name: DIP39
D
identifier
>" via the TCU firmware. The name can be changed in
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
Manual