Ethernet communication
7.4 External HMI Advanced
Note
There are no restrictions in terms of Ethernet topology within the SINUMERIK 840Di sl PCU
and HMI PCU.
Requirements
The following requirements must be fulfilled:
● There is an Ethernet connection between SINUMERIK 840Di sl PCU and HMI PCU and
● The communication parameters of the SINUMERIK 840Di sl PCU Ethernet interface with
HMI configuration
The configuration of HMI Advanced, with respect to the Ethernet connection to the
SINUMERIK 840Di sl, is performed as follows:
1. Start HMI Advanced.
2. Open the dialog for entering the IP address: Operating area switchover > Startup > HMI >
3. Enter the IP address of the interface by which the HMI communicates with the
190
both computers communicate.
which the HMI PCU is connected are known.
To check an Ethernet connection, see Subsection "Check Ethernet
Connection" (Page 188).
NCU link > NCU address
SINUMERIK 840Di sl.
Example:
Interface: Ethernet 2 (system network)
IP Address: 192.168.214.241 (default)
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0