Order of execution
Directories and programs are processed in the following order:
● Directories
1. C:\RunOEM\SeqOnce
2. C:\RunOEM\Seq
3. C:\RunOEM\ParOnce
4. C:\RunOEM\Par
● Programs
Data files
In addition to executable programs, you can also place data files in the subdirectories. They
will be opened in the application with which their file type is associated.
Example:
● File type: ".txt"-> Notepad
● File type: ".htm"-> Internet Explorer
5.4.6

User-specific HMI startup images

User-specific startup images can be displayed while the HMI is booting. The boot images
must be stored in bitmap format (*.BMP) in a defined directory structure.
Directory structure
The directory structure must be created under "F:\OEM\IB\DATA" according to the following
schema:
● F:\OEM\IB\DATA\<
Parameters: NCK type
The different NCK types are displayed depending on the directory name.
The following values may be used as directory names for the SINUMERIK 840Di sl:
● Default
● 5000
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
The programs within a subdirectory are started according to the chronological order in
which they were placed in the subdirectory.
NCK-Type
If a directory is created by default, the startup image stored in this directory will always be
displayed irrespective of the NCK type.
Under the Directory 5000 (ID for SINUMERIK 840Disl) stored startup images are only
displayed by the HMI application together with a SINUMERIK 840Di sl.
screen resolution
>\<
>\<
Power-On and Power-Up
5.4 Service Desktop
file name