7.5 MCP 483C IE
Display of the IP address
After the MCP has been electrically connected, all LEDs on the front side of the MCP flash
until communication is established between MCP and PLC.
To activate the display you must press the "Feed stop" and "Feed enable" keys
simultaneously. The Version No. of the current software version is then displayed with the
help of the continuously illuminated LEDs first. Press the "Enable spindle" key to switch to
the four positions of the IP address. One position of the IP address is displayed with each
key actuation, starting with the one having the max. value.
Example default IP address: 192.168.214.192
Pressing the "Spindle enable"
key n times
1
2
3
4
1) Display of the digit by means of continuously illuminated LEDs on the individual LED blocks
according to the following figure
Figure 7-6
Switch S1
With switch S1 you can select the type of handwheel that is to be operated on the module:
● Differential handwheels
● TTL handwheels
194
Display of the 1st digit of the IP address: 192
Switch S1 closed (delivery state)
Switch S1 open
1. digit
2. Digit
1)
1)
1
9
1
6
2
1
1
9
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
3. Digit
Digit of the IP
1)
address
2
1
8
2
4
3
2
4
Manual