11.2 Machine and setting data
Number
9219
9220
9221
9222
9231
9232
9233
9234
9235
9236
9237
9238
9239
9240
9241
9247
9248
References:
/FB/ Function Manual, Basic Functions, A2 various Interface Signals, Chapter "MMC
Machine data for protection levels"
Single data units
The protection level of individual machine and/or setting data can be modified in the file
SGUD.DEF.
Example:
The axial machine data item CTRLOUT_SEGMENT_NR requires protection level 3 for
reading and protection level 2 for writing.
Syntax:
REDEF $
APR n: Defining the protection level for reading (Read) the data
APW m: Defining the protection level for writing (Write) the data
SGUD.DEF file:
%_N_SGUD_DEF
M30
References:
/PGA/ Programming Manual, Work Planning, Chapter "File and Program Administration",
defining protection levels for user data (GUD)
362
Name
USER_CLASS_TEACH_IN
USER_CLASS_PRESET
USER_CLASS_CLEAR_RPA
USER_CLASS_WRITE_RPA
USER_CLASS_WRITE_RPA_1
USER_BEGIN_WRITE_RPA_1
USER_END_WRITE_RPA_1
USER_CLASS_WRITE_RPA_2
USER_BEGIN_WRITE_RPA_2
USER_END_WRITE_RPA_2
USER_CLASS_WRITE_RPA_3
USER_BEGIN_WRITE_RPA_3
USER_END_WRITE_RPA_3
USER_CLASS_WRITE_TOA_NAME
USER_CLASS_WRITE_TOA_TYPE
USER_CLASS_BASE_ZERO_OFF_PA
USER_CLASS_BASE_ZERO_OFF_MA
machine data string
;$PATH=/_N_DEF_DIR
REDEF $MA_CTRLOUT_SEGMENT_NO APR 3 APW 2
Name
TEACH IN
PRESET
Deleting R parameters
Write R parameters
Write protection for first RPA area
Start of the first RPA area
End of the first RPA area
Write protection for second RPA area
Start of the second RPA area
End of the second RPA area
Write protection for third RPA area
Start of the third RPA area
End of the third RPA area
Change tool designation and duplo
Change tool type
Basic offset PA
Basic offset MA
n
m
APR
APW