Siemens SINUMERIK 840Di sl Commissioning Manual page 64

Hide thumbs Also See for SINUMERIK 840Di sl:
Table of Contents

Advertisement

Hardware Descriptions
2.3 MCI board extension slot variation
Climatic environmental conditions
Heat dissipation
Temperature limits
Tested according to
Limits for relative humidity
Tested according to
Rate of temperature change
Condensation
Quality assurance
Vibrational load during operation
Class
Frequency range
Const. excursion/
acceleration
Tested as per
- module in PCU 50.3
Shock load during operation
Acceleration
Duration of nominal shock
Tested as per
- module in PCU 50.3
Note
The specified safety regulations, certifications, degree of protection and safety class only
apply if the module is plugged into a SINUMERIK PCU 50.3.
64
Open-circuit-ventilated
operation
5 ... 55°C
DIN IEC 68-2-1, DIN IEC 68-2-2
(DIN EN 60068-2-2), DIN IEC 68-2-14
5 ... .80%
DIN IEC 68-2-30
Per minute
Max. 1 K
Not permissible
to ISO 9001
3M4
10 ... 58 Hz/58... 200 Hz
0.075 mm / 1g
DIN EN 60068-2-6
50 m/s
2
30 ms
DIN EN 60068-2-6
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
Storage/transport
-40 ... 70°C
5 ... .95%
Per hour
Max. 10 K
Manual