840Di-specific data and functions
18.2 Expanded message frame configuration/evaluation of internal drive variables
Expanded message frame configuration
To configure the additional drive actual values, modify the standard configuration of the drive
e.g. starting at standard message frame 102 as follows with the SimoCom U commissioning
tool:
NOTICE
Before configuring the additional drive actual values, please ensure that the correct drive -
and if using a multiple axis module, the correct axis - was selected in the SimoCom U
commissioning tool.
● Activating the customizable message frame configuration
Figure 18-4
● Configuring the additional drive actual values
598
References:
/POS3/ User Manual - SIMODRIVE POSMO SI/CD/CA
– SimoCom U commissioning tool
References:
Online Help of SimoCom U
To activate the free message frame configuration, the message frame type of the
selected standard message frame in the PROFIBUS parameterization menu (menu
command Commission > Parameterization views > PROFIBUS Parameterization) is to be
replced by "0".
Activating the customizable message frame configuration
The drive utilization for PDA11 is configured via the selection list of the corresponding
parameter (PROFIDrive parameter P0916[x]) in the following figure.