Basic Commissioning Of The Plc - Siemens SINUMERIK 840Di sl Commissioning Manual

Hide thumbs Also See for SINUMERIK 840Di sl:
Table of Contents

Advertisement

Power-On and Power-Up
5.2 First power-up
5.2.2

Basic commissioning of the PLC

After the Service Desktop is active, the series commissioning file (*.arc) of one of the sample
applications delivered can be loaded for simplifying the PLC commissioning. An application
example includes the basic PLC program and the linking of one of the following MCP.
Path: < Installation path>\support\840dismp\
● PROFIBUS-MCP: 840disl_tb<version>_DPMCP.arc
● Ethernet MCP: 840disl_tb<version>_ETHMCP.arc
● Ethernet-MCP and HT 8: 840disl_tb<version>_ETHMCP_HT8.arc
Proceed as follows for loading the series commissioning file:
1. Start the "SinuCom NC" commissioning tool from the Windows taskbar: Start > Programs
2. Use SinuCom NC to load the series startup file PLC_SMP.ARC into the PLC.
This executes the PLC basic startup procedure. NC and PLC run in cyclic mode.
126
> SinuCom NC > SinuCom NC
Menu command: File > Archive > SeriesIBN-Archive > Read
Dialog: Read-in archive
– Radio button: Data management
– Button: "NEXT"
– Select the series commissioning file (*.arc)
– Button: "FINISH".
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0