Siemens SINUMERIK 840Di sl Commissioning Manual page 440

Hide thumbs Also See for SINUMERIK 840Di sl:
Table of Contents

Advertisement

NC Commissioning with HMI Advanced
11.5 Axes and spindles
Machine data
Table 11-38 Referencing: Machine data
Number
Name
General ($MN_ ... )
11300
JOG_INC_MODE_LEVELTRIGGRD
Channelspecific ($MC_ ... )
20700
REFP_NC_START_LOCK
Axisspecific ($MA_ ... )
30200
NUM_ENCS
30240
ENC_TYP
30242
ENC_IS_INDEPENDENT
31122
BERO_DELAY_TIME_PLUS
31123
BERO_DELAY_TIME_MINUS
34000
REFP_CAM_IS_ACTIVE
34010
REFP_CAM_DIR_IS_MINUS
34020
REFP_VELO_SEARCH_CAM
34030
REFP_MAX_CAM_DIST
34040
REFP_VELO_SEARCH_MARKER
34050
REFP_SEARCH_MARKER_REVERSE
34060
REFP_MAX_MARKER_DIST
34070
REFP_VELO_POS
34080
REFP_MOVE_DIST
34090
REFP_MOVE_DIST_CORR
34092
REFP_CAM_SHIFT
34100
REFP_SET_POS
34102
REFP_SYNC_ENCS
34110
REFP_CYCLE_NR
34120
REFP_BERO_LOW_ACTIVE
34200
ENC_REFP_MODE
34210
ENC_REFP_STATE
34220
ENC_ABS_TURNS_MODULO
34300
ENC_REFP_MARKER_DIST
34310
ENC_MARKER_INC
34320
ENC_INVERS
34330
REFP_STOP_AT_ABS_MARKER
35150
SPIND_DES_VELO_TOL
36302
ENC_FREQ_LIMIT_LOW
36310
ENC_ZERO_MONITORING
30250
ACT_POS_ABS
440
Name
INC/REF in jog/continuous mode
NC-Start disable without reference point
Number of encoders
Actual value encoder type
Encoder is independent
BERO delay time in plus direction
BERO delay time in minus direction
Axis with reference cam
Reference point approach in minus direction
Reference point approach velocity
Maximum distance to reference cam
Reference point creep speed
Direction reversal to reference cam
Maximum distance to reference mark; Maximum distance to two
reference marks with distance-coded scales
Reference point positioning velocity
Reference point distance/destination point for distancecoded
system
Reference point/absolute offset, distancecoded
Electronic reference cam shift for incremental measurement
systems with equidistant zero marks.
Reference point value
Actual value adjustment to the referencing measurement system
Axis sequence for channel-specific Homing
Polarity change of BERO
Referencing mode
Status of absolute encoder
Absolute encoder range for rotary encoders
Reference marker distance with distancecoded scales
Interval between two reference marks with distancecoded scales
Linear measuring system inverse to machine system
Distance-coded linear measuring system without destination
destination point
Spindle speed tolerance
Encoder limit frequency resynchronization
Zero mark monitoring
Absolute encoder position at time of deactivation.
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840die sl control

Table of Contents