Siemens SINUMERIK 840Di sl Commissioning Manual page 168

Hide thumbs Also See for SINUMERIK 840Di sl:
Table of Contents

Advertisement

PLC commissioning
6.3 Creating a SIMATIC S7 project
Dialog
Dialog: MPI/DP Properties
OK
NOTICE
If the interface X102 is not networked with PROFIBUS, then it must at least be networked
with MPI, in order to enable the internal communication via SOFTMC. See Subsection
"Parameterizing the MPI interface (X102) (optional)" (Page 169)
168
Tab: General
Name: <Designation of 2nd DP interface>
Group: Interface
Type: PROFIBUS
Button: "Properties..."
Dialog: Properties - PROFIBUS interface MPI/DP
Tab: Parameter
address: <Address>
Button: "New..."
Dialog: Properties - New Subnet PROFIBUS
Tab: Network settings
Data transfer rate: <Data transfer rate>
Profile: DP
OK
Tab: Mode
Radio button: <Mode>
OK
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840die sl control