Starting Up the PLC
11.1

Commissioning the PLC

11.1
Commissioning the PLC
By default, the user program of the SINUMERIK 802D only consists of a NOP ("no opera-
tion") instruction and is stored in the permanent memory. The user program addressing the
particular requirements of the machine is to be created by the user himself.
11.2
Start-up modes of the PLC
Table 11-1
Start-up modes
Selection
PCU
Switch-on menu
Start-up menu
(802D)
NCK start-up *
Normal booting
Normal booting
Booting
Booting
with default va-
with default values
lues
Booting
Booting
with saved data
with saved data
PLC stop
after POWER ON
PLC start-up **
Cold restart
Cold restart
and debug mode
Overall reset
11-164
PCU
PT PLC 802
(PC)
(802D)
PLC stop
possible ei-
ther in Run
or in Stop
Run (after
Stop)
PLC
Program
program
status
preselec-
tion
User pro-
Run
gram ***
User pro-
Run
gram ***
User pro-
Run
gram ***
unchanged
Stop
User pro-
Run
gram ***
User pro-
Stop
gram ***
User pro-
Run
gram ***
SINUMERIK 802D sl Instruction Manual (BA), 05/2005 Edition
Response
Retentive
MD for the
data
PLC in the
(battery bak-
user interface
ked)
unchanged
Acceptance of
the active
PLC MD
deleted
Default
PLC MD
saved
Saved PLC MD
data
unchanged
Acceptance of
the active
PLC MD
unchanged
Acceptance of
the active
PLC MD
unchanged
Acceptance of
the active
PLC MD
deleted
Acceptance of
the active
PLC MD
6FC5 397-0CP10-1BA0