Wiring
6.6.4

Intermediate circuit

Under "Connection cables", please note the requirements for the:
}
Cable cross sections
}
Insulation material
The connections for the intermediate circuit are
}
Not short circuit and earth fault proof
}
Not reverse polarity protected.
Connector X8
X8
Connector pin assignment
Output/input circuit
Servo Drive
Connection
Multi-axis systems
With multi-axis systems please note the specific conditions of your plant. On multi-axis sys-
tems, servo amplifiers can be interconnected via the intermediate circuit.
As with single-axis systems, max. cable runs can only be achieved if the material require-
ments are strictly observed.
Operating Manual PMCtendo DD5
1002236-EN-04
Pin
Designation
1
-DC
1 -DC
3
+Rbext/+DC
2 n.c.
3 +RBext
4 +RBint
5 -RB
X8
1
-DC
3
RBext/+DC
Servo Drive
Description
Intermediate circuit voltage -DC
Intermediate circuit voltage +DC
X8
Servo Drive
1
-DC
3
RBext/+DC
Intermediate circuit
Cable runs ≤ 200 mm:
Use unshielded single wires
(2.5 mm²)
Cable lengths > 200 mm:
Use shielded cables.