YASKAWA FSDrive-MV1000 Parameter Manual page 99

Super energy-saving medium-voltage ac drive, 2.4 kv class, 3 kv class, 4.16 kv class, 6 kv class, 11 kv class
Hide thumbs Also See for FSDrive-MV1000:
Table of Contents

Advertisement

u A2: User Parameters
A2-01 to A2-32: User Parameters 1 to 32
n
The user can select up to 32 parameters and assign them to parameters A2-01 through A2-32 frequently adjusted to
provide quicker access by eliminating the need to scroll through multiple menus. The User Parameter list can also track
the most recently edited settings and save those parameters to this list.
No.
A2-01 to A2-32
Table 2.5 Parameter Registered as User Parameters (A2-01 to A2-32) (Default Setting)
A2-
Default
A2-01
A1-02
A2-02
b1-01
A2-03
b1-02
A2-04
b1-03
A2-05
C1-01
A2-06
C1-02
A2-07
d1-01
A2-08
d1-02
A2-09
d1-03
A2-10
d1-04
A2-11
d1-17
A2-12
E1-04
A2-13
E1-05
A2-14
E1-06
A2-15
E1-09
A2-16
E1-13
Saving User Parameters
To save specific parameters to A2-01 through A2-32, set parameter A1-02 to 2 to allow access to all parameters, then
enter the parameter number to one of the A2-
to 1 to restrict access so users can only set and refer to the parameters saved as User Parameters.
A2-33: User Parameter Automatic Selection
n
Determines whether recently edited parameters are saved to the second half of the User Parameters (A2-17 to A2-32) for
quicker access.
No.
A2-33
User Parameter Automatic Selection
Setting 0: Do not save list of recently viewed parameters
Set A2-33 to 0 to manually select the parameters listed in the User Parameter group.
Setting 1: Save history of recently viewed parameters
By setting A2-33 to 1 to automatically save recently edited parameters A2-17 through A2-32. A total of 16 parameters
are saved with the most recently edited parameter set to A2-32, the second most recently to A2-31, and so on.
YASKAWA ELECTRIC TOEP C710687 03B FSDrive-MV1000 Parameter Guide
Name
User Parameters 1 to 32
Name
Control Method Selection
Frequency Reference Selection 1
Run Command Selection 1
Stopping Method Selection
Acceleration Time 1
Deceleration Time 1
Frequency Reference 1
Frequency Reference 2
Frequency Reference 3
Frequency Reference 4
Jog Frequency Reference
Maximum Output Frequency
Maximum Voltage
Base Frequency
Minimum Output Frequency
Base Voltage
parameters to assign it to the list of User Parameters. Finally, set A1-01
Name
Setting Range
b1-01 to o4-
A2-
Default
A2-17
E2-01
Motor Rated Current
A2-18
E2-04
Number of Motor Poles
A2-19
E2-11
Motor Rated Power
A2-20
H4-02
Analog Output 1 Gain
A2-21
H4-12
Analog Output 2 Gain
A2-22
H4-22
Analog Output 3 Gain
A2-23
H4-32
Analog Output 4 Gain
A2-24
L1-01
Motor Overload Protection Selection
A2-25
L3-04
Stall Prevention during Deceleration
A2-26
A2-27
A2-28
A2-29
A2-30
A2-31
A2-32
Setting Range
0 or 1
2.1 A: Initialization
Default
0
Name
Default
0
99