1.3 Parameter Table
No.
Name
(Addr.)
MEMOBUS/
U4-22
Modbus
(7DEH)
Communications
Reference
Communication
U4-23
Option Card
(7DFH)
Reference
U4-33
Transformer
(1040H)
Temperature
U4-90
Calendar Year
(30D0H)
U4-91
Calendar Month
(30D1H)
and Day
U4-92
Calendar Hour
(30D2H)
and Minute
U4-93
Calendar Minute
(30D3H)
and Second
U5-01
PID Feedback
(57H)
U5-02
PID Input
(63H)
U5-03
PID Output
(64H)
U5-04
PID Setpoint
(65H)
Value
U5-05
Differential PID
(7D2H)
Feedback
U5-06
PID Adjusted
(7D3H)
Feedback
U6-01
Motor Secondary
(51H)
Current (Iq)
U6-02
Motor Excitation
(52H)
Current (Id)
U6-03
ASR Input
(54H)
U6-04
ASR Output
(55H)
U6-05
Output Voltage
(59H)
Reference (Vq)
U6-06
Output Voltage
(5AH)
Reference (Vd)
82
All Modes
Displays the drive control data set by MEMOBUS/Modbus
communications register no. 0001H as a four-digit hexadecimal number.
All Modes
Displays drive control data set by an option card as a four-digit
hexadecimal number.
All Modes
Displays the detected transformer temperature value.
All Modes
Displays the calendar year.
All Modes
Displays the calendar month and day.
All Modes
Displays the calendar hour and minute.
All Modes
Displays the calendar minute and second.
All Modes
Displays the PID feedback value.
All Modes
Displays the amount of PID input (deviation between PID setpoint and
feedback).
All Modes
Displays PID control output.
All Modes
Displays the PID setpoint.
All Modes
Displays the 2nd PID feedback value if differential feedback is used
(H3-
= 16).
All Modes
Displays the difference of both feedback values if differential feedback is
used (U5-01 - U5-05).
If differential feedback is not used, then U5-01 and U5-06 will be the
same.
U6: Control Monitors
All Modes
Displays the value of the motor secondary current (Iq). Motor rated
secondary current is 100%.
V/f
OLV
Displays the value calculated for the motor excitation current (Id). Motor
rated secondary current is 100%.
V/f
OLV
Displays the input and output values when using ASR control.
V/f
OLV
Output voltage reference (Vq) for the q-axis.
V/f
OLV
Output voltage reference (Vd) for the d-axis.
Description
U5: PID Monitors
CLV
CLV
CLV
CLV
YASKAWA ELECTRIC TOEP C710687 03B FSDrive-MV1000 Parameter Guide
Analog Output
Level
common_
No signal output
available
common_
No signal output
available
common_
10 V: 200.0°C
common_
No signal output
available
common_
No signal output
available
common_
No signal output
available
common_
No signal output
available
10 V: Max
common_
frequency
common_
10 V: Max
frequency
common_
10 V: Max
frequency
10 V: Max
common_
frequency
common_
10 V: Max
frequency
common_
10 V: Max
frequency
10 V: Motor
common_
secondary rated
current
10 V: Motor
common
secondary rated
current
10 V: Max.
output frequency
10 V: Motor
common
secondary rated
current
10 V: Drive
common
rated voltage
10 V: Drive
common
rated voltage
Unit
Page
0.1°C
1
01.01
01.01
01.01
0.01%
0.01%
0.01%
0.01%
0.01%
0.01%
0.1%
0.1%
0.01%
1 V
1 V