d5-03: Speed Limit Selection
n
Determines how the speed limit is set.
No.
d5-03
Setting 1: Frequency Reference Input
The frequency reference value at the active reference source (digital operator, External reference 1 or External reference
2) will be used as speed limit. Note that in this case all settings for accel/decel times (C1-01 to C1-08) and S-curves
(C2-01 to C2-04) will apply for the speed limit.
Setting 2: Parameter d5-04
The speed limit is set by parameter d5-04.
d5-04: Speed Limit
n
Sets the speed limit during torque control if parameter d5-03 is set to 2.
on page
151.
No.
d5-04
d5-05: Speed Limit Bias
n
Applies a bias set as a percentage of the maximum output frequency to the speed limit value.
No.
d5-05
d5-06: Speed/Torque Control Switchover Time
n
Sets the delay time for switching between Speed Control and Torque Control.
No.
d5-06
d5-08: Unidirectional Speed Limit Bias
n
Selects how the speed limit bias is applied.
No.
d5-08
Setting 0: Disabled
The speed limit bias is applied in the speed limit direction and the opposite direction.
Setting 1: Enabled
The speed limit bias is applied in the opposite direction of the speed limit only.
YASKAWA ELECTRIC TOEP C710687 03B FSDrive-MV1000 Parameter Guide
Name
Speed Limit Selection
Name
Speed Limit
Name
Speed Limit Bias
Name
Speed/Torque Control Switchover Time
Name
Unidirectional Speed Limit Bias
2.4 d: Reference Settings
Setting Range
1 or 2
Refer to Speed Limitation and Speed Limit Bias
Setting Range
-120 to 120%
Setting Range
0 to 120%
Setting Range
0 to 1000 ms
Setting Range
0 or 1
Default
1
Default
0%
Default
10%
Default
0 ms
Default
1
153