YASKAWA FSDrive-MV1000 Parameter Manual page 61

Super energy-saving medium-voltage ac drive, 2.4 kv class, 3 kv class, 4.16 kv class, 6 kv class, 11 kv class
Hide thumbs Also See for FSDrive-MV1000:
Table of Contents

Advertisement

H3-
Function
Setting
1F
Through Mode
No.
Name
(Addr.)
H4-01
Analog Output 1
(3050H)
Monitor Selection
H4-02
Analog Output 1
(3051H)
Gain
H4-03
Analog Output 1
(3052H)
Bias
H4-04
Analog Output 1
(3053H)
Cell Selection
Analog Output 1
H4-05
Signal Level
(3054H)
Selection
H4-11
Analog Output 2
(305AH)
Monitor Selection
H4-12
Analog Output 2
(305BH)
Gain
H4-13
Analog Output 2
(305CH)
Bias
H4-14
Analog Output 2
(305DH)
Cell Selection
Analog Output 2
H4-15
Signal Level
(305EH)
Selection
H4-21
Analog Output 3
(3064H)
Monitor Selection
H4-22
Analog Output 3
(3065H)
Gain
YASKAWA ELECTRIC TOEP C710687 03B FSDrive-MV1000 Parameter Guide
H3 Analog Input Settings
All Modes
Set this value when using the terminal in the pass-through mode.
H4: Analog Outputs
All Modes
Sets the monitor signal from analog output 1.
Set the desired monitor parameter to the digits available in U -
example, enter "103" for U1-03.
All Modes
Sets the signal level at analog output 1 that is equal to 100% of the selected
monitor value.
All Modes
Sets the bias value added to analog output 1 signal.
All Modes
Sets the number of the power cell to be output from analog output 1. This
setting is effective when 9
Output 1 Monitor Selection).
All Modes
Sets the signal level output 1.
0: 0 to 10 V
1: -10 to 10 V
All Modes
Sets the monitor signal from analog output 2. Set this parameter to the last
three digits ( -
) of the desired U -
are available only in certain control modes.
All Modes
Sets the gain for voltage output via analog output 2.
All Modes
Sets the amount of bias added to the voltage output via analog output 2.
All Modes
Sets the number of the Power Cell to be output from analog output 2. This
setting is effective when 9
Output 2 Monitor Selection).
All Modes
Sets the signal level for analog output 2.
0: 0 to 10 V
1: -10 to 10 V
All Modes
Sets the monitor signal for output from analog output 3. Set this parameter to
the last three digits ( -
) of the desired U -
parameters are available only in certain control modes.
All Modes
Sets the gain for voltage output via analog output 3.
Description
Description
(Power C ell) has been set for H4-01 (Analog
parameter. Some U parameters
(Power Cell) has been set for H4-11 (Analog
parameter. Some U
1.3 Parameter Table
common_
Setting
common_
Default: 102
Min: 000
. For
Max: 999
Default: 100.0%
common_
Min: -999.9%
Max: 999.9%
Default: 0.0%
common_
Min: -999.9%
Max: 999.9%
common_
Default: 1
Min: 1
Max: 15
common_
Default: 1
Min: 0
Max: 1
common_
Default: 103
Min: 000
Max: 999
Default: 100.0%
common_
Min: -999.9%
Max: 999.9%
Default: 0.0%
common_
Min: -999.9%
Max: 999.9%
common_
Default: 1
Min: 0
Max: 15
common_
Default: 1
Min: 0
Max: 1
common_
Default: 000
Min: 000
Max: 999
Default: 100.0%
common_
Min: -999.9%
Max: 999.9%
Page
197
Page
198
198
198
198
200
198
198
198
198
200
198
198
61

Advertisement

Table of Contents
loading

Table of Contents