YASKAWA FSDrive-MV1000 Parameter Manual page 45

Super energy-saving medium-voltage ac drive, 2.4 kv class, 3 kv class, 4.16 kv class, 6 kv class, 11 kv class
Hide thumbs Also See for FSDrive-MV1000:
Table of Contents

Advertisement

No.
Name
(Addr.)
Contact Output 1
F5-01
(Terminal P1-PC)
(399H)
Output Selection
Contact Output 2
F5-02
(Terminal P2-PC)
(39AH)
Output Selection
Contact Output 3
F5-03
(Terminal P3-PC)
(39BH)
Output Selection
Contact Output 4
F5-04
(Terminal P4-PC)
(39CH)
Output Selection
Contact Output 5
F5-05
(Terminal P5-PC)
(39DH)
Output Selection
Contact Output 6
F5-06
(Terminal P6-PC)
(39EH)
Output Selection
Contact Output 7
F5-07
(Terminal M1-M2)
(39FH)
Output Selection
Contact Output 8
F5-08
(Terminal M3-M4)
(3A0H)
Output Selection
F5-09
DO-A3 Output
(3A1H)
Mode Selection
• F6-01 to F6-03 and F6-06 to F6-08 are parameters used for DeviceNet and PROFIBUS-DP. Other parameters in the F6 group are used for
communication-protocol-specific settings.
• For details, refer to the technical manual of each communication option card.
Communications
F6-01
Error Operation
(3A2H)
Selection
External Fault from
F6-02
Comm. Option
(3A3H)
Detection Selection
External Fault from
F6-03
Comm. Option
(3A4H)
Operation Selection
F6-04
bUS Error Detection
(3A5H)
Time
Torque Reference/
F6-06
Torque Limit
(3A7H)
Selection from
Comm. Option
F6-07
NetRef/ComRef
(3A8H)
Function Selection
YASKAWA ELECTRIC TOEP C710687 03B FSDrive-MV1000 Parameter Guide
F5: Contact Output Card (DO-A3)
All Modes
Sets the function for contact outputs 1 to 8 (terminals P1-PC to P6-PC,
M1-M2, and M3-M4).
All Modes
0: Output terminals are each assigned separate output functions.
1: Binary code output
2: Use output terminal functions selected by parameters F5-01 through
F5-08.
F6: Communication Option Cards
All Modes
0: Ramp to stop. Decelerate to stop using the deceleration time in C1-02.
1: Coast to stop
2: Fast Stop. Decelerate to stop using the deceleration time in C1-09.
3: Alarm only
All Modes
0: Always detected
1: Detection during run only
All Modes
0: Ramp to stop. Decelerate to stop using the deceleration time in C1-02.
1: Coast to stop
2: Fast Stop. Decelerate to stop using the deceleration time in C1-09.
3: Alarm only
All Modes
Sets the delay time for error detection if a bus error (Option Communication
Error) occurs.
V/f
OLV
0: Disabled. Torque reference/limit from the host controller disabled.
1: Enabled. Torque reference/limit from the host controller enabled.
All Modes
0: Multi-step reference disabled
1: Multi-step reference enabled
Description
CLV
1.3 Parameter Table
Setting
Default: 0
Min: 0
Max: 1FF
Default: 1
Min: 0
Max: 1FF
Default: 2
Min: 0
Max: 1FF
Default: 4
Min: 0
common_
Max: 1FF
Default: 6
Min: 0
Max: 1FF
Default: 37
Min: 0
Max: 1FF
Default: F
Min: 0
Max: 1FF
Default: F
Min: 0
Max: 1FF
common_
Default: 0
Min: 0
Max: 2
common_
Default: 1
Min: 0
Max: 3
common_
Default: 0
Min: 0
Max: 1
common_
Default: 1
Min: 0
Max: 3
Default: 2.0 s
common_
Min: 0.0 s
Max: 5.0 s
Default: 0
common
Min: 0
Max: 1
common_
Default: 0
Min: 0
Max: 1
Page
168
168
168
168
168
168
168
168
168
169
169
169
170
170
45