YASKAWA FSDrive-MV1000 Parameter Manual page 41

Super energy-saving medium-voltage ac drive, 2.4 kv class, 3 kv class, 4.16 kv class, 6 kv class, 11 kv class
Hide thumbs Also See for FSDrive-MV1000:
Table of Contents

Advertisement

No.
Name
(Addr.)
E4-03
Motor 2 Rated
(323H)
No-Load Current
E4-04
Motor 2 Motor Poles
(324H)
Motor 2
E4-05
Line-to-Line
(325H)
Resistance
E4-06
Motor 2 Leakage
(326H)
Inductance
Motor 2 Motor
E4-07
Iron-Core Saturation
(343H)
Coefficient 1
Motor 2 Motor
E4-08
Iron-Core Saturation
(344H)
Coefficient 2
E4-09
Motor 2 Mechanical
(33FH)
Loss
E4-10
Motor 2 Iron Loss
(340H)
E4-11
Motor 2 Rated
(327H)
Power
<3> Parameter setting value is not reset to the default value when the drive is initialized (A1-03 = 1110/2220).
<6> Default setting value is determined by o2-04, Drive Model Selection.
<10> Default setting is determined A1-02, Control Method Selection.
<16> Default setting is determined by A1-02, Control Method Selection, and o2-04, Drive Model Selection.
<21> Parameter ignored when E1-11, Motor 1 Mid Output Frequency 2, and E1-12, Motor 1 Mid Output Frequency Voltage 2, are set to 0.0.
<24> Parameter ignored when E3-11, Motor 2 Mid Output Frequency 2, and E3-12, Motor 2 Mid Output Frequency Voltage 2, are set to 0.0.
<25> Default setting is determined by E3-01, Motor 2 Control Mode. The value shown here is for V/f Control.
<27> When Auto-Tuning is performed, E1-13 and E1-05 will be set to the same value.
<67> The drive changes these settings when Auto-Tuning is performed (Rotational Auto-Tuning, Stationary Auto-Tuning).
<69> When Auto-Tuning for motor 2 is performed, E3-13 and E3-05 will be set to the same value.
YASKAWA ELECTRIC TOEP C710687 03B FSDrive-MV1000 Parameter Guide
All Modes
Sets the no-load current for motor 2. Automatically set during Auto-Tuning.
All Modes
Sets the number of poles of motor 2. Automatically set during Auto-Tuning.
All Modes
Sets the phase-to-phase resistance for motor 2. Automatically set during
Auto-Tuning.
All Modes
Sets the voltage drop for motor 2 due to motor leakage inductance as a
percentage of rated voltage.
V/f
OLV
Set to the motor iron saturation coefficient at 50% of magnetic flux for motor
2. Automatically set during Auto-Tuning.
V/f
OLV
Set to the motor iron saturation coefficient at 75% of magnetic flux for motor
2. Automatically set during Auto-Tuning.
V/f
OLV
Sets the motor mechanical loss for motor 2 as a percentage of motor rated
power (kW).
Adjust the setting in the following circumstances:
• When there is a large amount of torque loss due to motor bearing friction
• When there is a large amount of torque loss in a fan or pump application
V/f
OLV
Sets the motor iron loss.
All Modes
Sets the motor rated capacity in kW. Automatically set during Auto-Tuning.
Description
CLV
CLV
common
CLV
common
CLV
common
1.3 Parameter Table
Setting
Default:
<6>
common_
Min: 0 A
Max: E4-01
Default: 4
common_
Min: 2
Max: 48
common_
Default:
<6>
Min: 0.000 Ω
Max: 65.000 Ω
Default:
common_
<6>
Min: 0.0%
Max: 40.0%
Default: 0.50
common
Min: 0.00
Max: 0.50
Default: 0.75
Min: E4-07
Max: 0.75
Default: 0.0%
Min: 0.0%
Max: 10.0%
Default:
<6>
Min: 0 W
Max: 65535 W
Default:
<6>
common_
Min: 0 kW
Max: 65000 kW
Page
161
161
161
162
162
162
162
162
162
41