YASKAWA FSDrive-MV1000 Parameter Manual page 171

Super energy-saving medium-voltage ac drive, 2.4 kv class, 3 kv class, 4.16 kv class, 6 kv class, 11 kv class
Hide thumbs Also See for FSDrive-MV1000:
Table of Contents

Advertisement

2.7
H: Terminal Functions
H parameters are used to assign functions to the external terminals.
u H1: Contact Inputs
H1-02 to H1-16: Functions for Contact Inputs 2 to 16
n
These parameters assign functions to the contact inputs. The various functions and settings are listed below in
No.
H1-02
Contact Input 2 Function Selection
H1-03
Contact Input 3 Function Selection
H1-04
Contact Input 4 Function Selection
H1-05
Contact Input 5 Function Selection
H1-06
Contact Input 6 Function Selection
H1-07
Contact Input 7 Function Selection
H1-08
Contact Input 8 Function Selection
H1-09
Contact Input 9 Function Selection
H1-10
Contact Input 10 Function Selection
H1-11
Contact Input 11 Function Selection
H1-12
Contact Input 12 Function Selection
H1-13
Contact Input 13 Function Selection
H1-14
Contact Input 14 Function Selection
H1-15
Contact Input 15 Function Selection
H1-16
Contact Input 16 Function Selection
<1> The default setting is set to 73 and cannot be changed under the following conditions.
The drive software version is S0108 and later.
o2-09 is set to 2.
Setting
1
LOCAL/REMOTE Selection
2
External Reference 1/2 Selection
3
Multi-Step Speed Reference 1
4
Multi-Step Speed Reference 2
5
Multi-Step Speed Reference 3
6
Jog Reference Selection
7
Accel/Decel Time Selection 1
8
Baseblock Command (N.O.)
9
Baseblock Command (N.C.)
A
Accel/Decel Ramp Hold
B
Drive Overheat Alarm (oH2)
C
Analog Terminal Input Selection
E
ASR Integral Reset
F
Through Mode
10
Up Command
11
Down Command
12
Forward Jog
13
Reverse Jog
14
Fault Reset
15
Fast Stop (N.O.)
16
Motor 2 Selection
17
Fast Stop (N.C.)
18
Timer Function Input
19
PID Disable
YASKAWA ELECTRIC TOEP C710687 03B FSDrive-MV1000 Parameter Guide
Table 2.20 Contact Input Parameters
Name
Setting Range
Table 2.21 Contact Input Terminal Settings
Function
1 to 9F
40: Forward Run Command (2-Wire Sequence)
0 to 9F
6A: Drive Enable
0 to 9F
70: Drive Enable 2
0 to 9F
F: Through Mode
0 to 9F
F: Through Mode
0 to 9F
F: Through Mode
0 to 9F
F: Through Mode
0 to 9F
F: Through Mode
0 to 9F
F: Through Mode
0 to 9F
F: Through Mode
0 to 9F
F: Through Mode
0 to 9F
F: Through Mode
0 to 9F
F: Through Mode
0 to 9F
F: Through Mode
0 to 9F
F: Through Mode
Page
Setting
172
31
PID Integral Hold
172
32
Multi-Step Speed Reference 4
172
33
Thermostatic Switch (N.C.)
172
34
PID Soft Starter Cancel
172
35
PID Input Level Selection
172
40
Forward Run Command (2-Wire Sequence)
172
41
Reverse Run Command (2-Wire Sequence)
172
42
Run Command (2-Wire Sequence 2)
172
43
FWD/REV Command 2 (2-Wire Sequence 2)
173
44
Add Offset Frequency 1
173
45
Add Offset Frequency 2
173
46
Add Offset Frequency 3
173
60
DC Injection Braking Command
173
61
External Search Command 1
173
62
External Search Command 2
173
63
Field Weakening
175
67
Communications Test Mode
175
6A
Drive Enable
175
70
Drive Enable 2
175
71
Speed/Torque Control Switch
176
73
Door Switch NC
175
75
Up 2 Command
176
76
Down 2 Command
176
77
ASR Gain Switch
2.7 H: Terminal Functions
Default
<1>
Function
Table
2.21.
Page
178
178
178
178
178
178
178
178
178
178
178
178
178
179
179
179
179
179
179
179
179
179
179
180