1.3 Parameter Table
No.
Name
(Addr.)
Analog Output 5
F4-01
(Terminal V1)
(391H)
Monitor Selection
F4-02
Analog Output 5
(392H)
(Terminal V1) Gain Sets the gain for voltage output via analog output 5 (terminal V1).
F4-03
Analog Output 5
(3080H)
(terminal V1) Bias
F4-04
Analog Output 5
(3081H)
(Terminal V1) Cell
Selection
Analog Output 5
F4-05
(Terminal V1)
(3082H)
Signal Level
Selection
Analog Output 6
F4-11
(Terminal V2)
(3083H)
Monitor Selection
F4-12
Analog Output 6
(3084H)
(Terminal V2) Gain Sets the gain for voltage output via analog output 6 (terminal V2).
F4-13
Analog Output 6
(3085H)
(terminal V2) Bias
F4-14
Analog Output 6
(3086H)
(Terminal V2) Cell
Selection
Analog Output 6
F4-15
(Terminal V2)
(3087H)
Signal Level
Selection
44
F4: Analog Monitor Card (AO-A3)
All Modes
Sets the monitor signal for output from analog output 5 (terminal V1). Set
this parameter to the last three digits ( -
monitor. Some U parameters are available only in certain control modes.
All Modes
All Modes
Sets the amount of bias added to the voltage output via analog output 5
(terminal V1).
All Modes
Sets the number of the power cell to be output from analog output 5
(terminal V1). This setting is effective when 9
for F4-01 (Analog Output 5 (terminal V1) Monitor Selection).
All Modes
Sets the signal level for analog output 5 (terminal V1).
0: 0 to 10 V
1: -10 to 10 V
All Modes
Sets the monitor signal for output from analog output 6 (terminal V2). Set
this parameter to the last three digits ( -
monitor. Some U parameters are available only in certain control modes.
All Modes
All Modes
Sets the amount of bias added to the voltage output via analog output 6
(terminal V2).
All Modes
Sets the number of the power cell to be output from analog output 6
(terminal V2). This setting is effective when 9
for F4-11 (Analog Output 6 (Terminal V2) Monitor Selection).
All Modes
Sets the signal level for analog output 6 (terminal V2).
0: 0 to 10 V
1: -10 to 10 V
Description
) of the desired U -
(power cell) has been set
) of the desired U -
(power cell) has been set
YASKAWA ELECTRIC TOEP C710687 03B FSDrive-MV1000 Parameter Guide
Setting
common_
Default: 102
Min: 000
Max: 999
Default: 100.0%
common_
Min: -999.9%
Max: 999.9%
common_
Default: 0.0%
Min: -999.9%
Max: 999.9%
common_
Default: 1
Min: 1
Max: 15
common_
Default: 1
Min: 0
Max: 1
common_
Default: 103
Min: 000
Max: 999
Default: 100.0%
common_
Min: -999.9%
Max: 999.9%
Default: 0.0%
common_
Min: -999.9%
Max: 999.9%
common_
Default: 1
Min: 1
Max: 15
common_
Default: 1
Min: 0